Overview

  • Current Power – displays current output of power in Watts
  • If you have a Fronius smart meter installed, it will also display export in Watts to the grid and consumption being used on site in Watts.
  • If there is a battery installed, it will display the battery’s SOC (state of charge)
  • Energy Balance Today – displays production in green, if there is a smart meter installed, you will see an outline for consumption across the graph, the grey across the graph is self-consumption (consumption of energy from your solar production)
  • Earning – shows earnings/savings, if you have a smart meter and have set up currency and feed in tariffs on your inverter, this will display your savings in the currency you have set up
  • CO2 Savings Total – if you have CO2 factor enabled in your settings, this field will display your CO2 savings in tonne, trees and kilometres

Analysis

View your inverter information here bye selecting Analysis > History

  • Select the device (there can be various devices if you have a Fronius smart meter or Ohmpilot as well as your inverter)
  • Select the channel you would like to see
  • Current AC L1/L2/L3 – this is the current in amperage from your inverter to the grid
  • Current DC MPP1 – this is the current in amperage from your Maximum Power Point Tracker 1 on your solar array, to the inverter
  • Current DC MPP2 – this is the current in amperage from your Maximum Power Point Tracker 2 on your solar array, to the inverter
  • Power MPP1 – this is power output in watts from your Maximum Power Point Tracker 1 on your solar array, to the inverter
  • Power MPP2 – this is power output in watts from your Maximum Power Point Tracker 2 on your solar array, to the inverter
  • Total Power – this is the total power output in watts across your solar array
  • Voltage AC L1/L2/L3 – this is the current AC voltage from your mains
  • Voltage DC MPP1 – this is the voltage from your Maximum Power Point Tracker 1 on your solar array, to the inverter
  • Voltage DC MPP2 – this is the voltage from your Maximum Power Point Tracker 2 on your solar array, to the inverter
  • Consumption – If you have a Fronius smart meter installed, this option will display your consumption of energy on the property
  • Power from grid – if you have a Fronius smart meter installed, this option will show energy imported from your electricity provider
  • Power to grid – If you have a Fronius smart meter installed, this will show energy exported to your electricity provider
  • Power from battery – If you have a battery installed, this option will show you your battery consumption
  • Power to battery – If you have a battery installed, this option will show you how much power (from your solar or from the grid) is being used to charge the battery
  • Reports – you can set up reports on an interval schedule to display production, current, voltage and other helpful system information

 

Service Messages

Any system issues or service messages will be displayed here. If a message state appears it will also be emailed to you.

 

Settings

A selection of settings is available for you to update if you need. Most settings would have been set upon installation.